  "object_id": "c05-inlet-geometry",
  "svg": "c05-inlet-geometry.svg",
  "kind": "conditional_layout_method",
  "diameter_input": {
    "D": 12,
    "unit": "in",
    "authority": "stipulated inletsizeinillustration;notactualID/ODdefinitionforproject"
  },
  "base_run": {
    "L": 4,
    "unit": "ft",
    "method": "4D=48in=4ft"
  },
  "arrangements": [
    {
      "id": "A",
      "feature": "horizontalapproachparallel toshaft",
      "factor": 1,
      "straight_ft": 4,
      "shown": true
    },
    {
      "id": "B",
      "feature": "horizontalapproachperpendicular toshaft",
      "factor": 1.5,
      "straight_ft": 6,
      "shown": true
    },
    {
      "id": "C",
      "feature": "shownvalve inapproach",
      "factor": 1.5,
      "straight_ft": 6,
      "shown": true
    },
    {
      "id": "D",
      "feature": "perpendicular mainapproach withoffsetbeforeverticalriser",
      "factor": 1.75,
      "straight_ft": 7,
      "shown": false
    },
    {
      "id": "E",
      "feature": "parallel mainapproach withoffsetbeforeverticalriser",
      "factor": 2,
      "straight_ft": 8,
      "shown": false
    }
  ],
  "horizontal_piece": {
    "factor_D": 10,
    "example_ft": 10,
    "scope": "separateshownhorizontalpiece,notverticalrun oruniversalstraightminimum"
  },
  "graphical_scope": "Three schematic elevationpanelsrepresentrunheight andfeaturelabels only;approachplanorientationdescribedbytext,notinferredfromthis2D projection",
  "conditions": [
    "12in/4Dparticulargas-compressorbasis only",
    "No inletflowqualification,actualfloorheight,pressureloss orfabricationgeometry",
    "3Dtestcontext,washwatercould10ft andconditionalvanequarter-length areseparatecriteria",
    "Use selectedsupplier/gas/velocity/temperature/geometryacceptancebasis"
  ]
}